Saturday, May 18, 2013
 

Laser Diffraction

Microtrac X-100

Services - Laser Diffraction

Features:
  • Analytical range wet: approx. 0.1 - 700µm
  • Can analyze liquid suspension and dry powder
    suspended in organic or inorganic solvents, emulsions
  • Reports particle size data on a Volume basis
Applications:
  • Particle size distribution measurement
  • Quality Control
Recommendations for Optimal Output:

  • Supply Refractive Index (can analyze without)
  • Recommended amount of sample needed:
    1 to 5 grams (dry sample) 250 to 500 mL (wet sample)
 

Microtrac X-100

Services - Laser Diffraction

Features:
  • Analytical range wet: approx. 0.1 - 700µm
  • Can analyze liquid suspension and dry powder
    suspended in organic or inorganic solvents, emulsions
  • Reports particle size data on a Volume basis
Applications:
  • Particle size distribution measurement
  • Quality Control
Recommendations for Optimal Output:

  • Supply Refractive Index (can analyze without)
  • Recommended amount of sample needed:
    1 to 5 grams (dry sample) 250 to 500 mL (wet sample)
   

Beckman Coulter LS13 320

Services - Laser Diffraction

Features:
  • Analytical range wet: approx. 0.01µm - 2000µm
  • Analytical range dry: approx. 0.1µm - 2000µm
  • Can analyze liquid suspension (organic or inorganic
    solvents), emulsion or dry powder
  • Reports particle size data on a Volume basis
Applications:
  • Particle size distribution measurement
  • Quality Control
Recommendations for Optimal Output:
  • Supply Refractive Index (can analyze without)
  • Recommended amount of sample needed: 5 to 10 grams
    (dry sample) 500 to 750 mL (wet sample)

 

Malvern Mastersizer 2000

Services - Laser Diffraction

Features:
  • Analytical range wet: approx. 0.02µm - 2000µm
  • Analytical range dry: approx. 0.2µm - 2000µm microns
  • Can analyze liquid suspension (organic or inorganic solvents),
    emulsion or dry powder
  • Reports particle size data on a Volume basis
  • Computer program - CFR Part 11
Applications:
  • Particle size distribution measurement
  • Quality Control
Recommendations for Optimal Output:

  • Supply Refractive Index (can analyze without)
  • Recommended amount of sample needed: 1 to 10 grams
    (dry sample)250 to 500 mL (wet sample)

   

Malvern Mastersizer S

Services - Laser Diffraction

Features:
  • Analytical range wet: approx. 0.05µm - 900µm
  • Analytical range dry: approx. 0.5µm - 900µm
  • Can analyze liquid suspension (organic or inorganic solvents), emulsion or dry powder
  • Reports particle size data on a Volume basis
Applications:
  • Particle size distribution measurement
  • Quality Control
Recommendations for Optimal Output:

  • Provide particle's Refractive Index (can analyze without)
  • Recommended amount of sample needed: 1 to 10 grams (dry sample) 250 to 500 mL (wet sample)